Product characteristics:
Maximum inlet steam pressure: 14Mpa
Maximum inlet steam temperature: 535℃
Maximum capacity: 100MW
Exhaust steam can be used for heating purpose.
Can be used for power generating or driving other equipment.
Customized order
Remote monitoring and diagnose service
NO. | Model | Capacity(MW) | Inlet | ExhaustPressure(Mpa) | Speed(r/min) |
|
|
| Pressure(MPa) | Temp(℃) |
|
|
1 | B0.4~B1.6 | 0.4~1.6 | 1.2~4 | 300~470 | 0.2~1.27 | 6500 |
2 | B0.8~B1.6 | 0.8~1.6 | 3.5~6.5 | 270~435 | 1.1~2.5 | 6500 |
3 | B1.6~B3 | 1.6~3 | 2.3~4.9 | 300~470 | 0.2~2.5 | 5600 |
4 | B3~B8 | 3~8 | 2.3~4.9 | 300~470 | 0.2~2.5 | 3000 |
5 | B3~B8 | 3~8 | 3.5~6.5 | 390~470 | 0.5~2.5 | 3000 |
6 | B3~B8 | 3~8 | 4.9~10 | 435~535 | 0.5~5 | 3000 |
7 | B9~B12 | 9~12 | 2.3~5 | 390~470 | 0.2~2.5 | 3000 |
8 | B9~B12 | 9~12 | 4.9~10 | 435~535 | 0.5~5 | 3000 |
9 | B12~B18 | 12~18 | 2.3~5 | 390~470 | 0.2~2.5 | 3000 |
10 | B12~B18 | 12~18 | 4.9~10 | 435~535 | 0.5~5 | 3000 |
11 | B20~B30 | 20~30 | 2.3~5 | 390~470 | 0.2~2.5 | 3000 |
12 | B20~B30 | 20~30 | 4.9~10 | 435~535 | 0.5~5 | 3000 |
13 | B40~B50 | 40~50 | 4.9~10 | 435~535 | 0.5~5 | 3000 |